Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Chinese Journal of Urology ; (12): 840-844, 2022.
Article in Chinese | WPRIM | ID: wpr-993931

ABSTRACT

Objective:To explore the potential relationship of urethral pressure profilometry and the complications of artificial urethral sphincter (AUS) implantation.Methods:The clinical data of patients who underwent AUS implantation in Beijing Hospital from March 2019 to March 2022 were retrospectively analyzed. All the patients were male. The average course of disease was 43.1 months(ranging 11-120 months). The average age was (68.6±13.2) years. The median number of pads used was 4.5 (3.0, 6.0). The preoperative maximum urethral pressure (MUP) was (84.6±25.5) cmH 2O, and the maximum urethral closure pressure (MUCP) was 51.0 (41.0, 74.0) cmH 2O. AUS implantation was performed through a single perineal incision in all patients. The sleeve size was mainly determined by the measured urethral circumference of the patient. After installation of all components, the urethral pressure profilometry was performed under the state of device inactivation and activation. The pump was activated 6 weeks after the operation, and telephone follow-up was performed 3 months after the activation of the device. The urinary control and complications were recorded. The results of follow-up were compared with the results of urethral pressure profilometry, and the preliminary conclusions were drawn. Results:In this study, 3 patients (20%) received 4.0cm cuffs, 10 patients (66.7%) received 4.5cm cuffs, and 2 patients (13.3%) received 5.0cm cuffs. The MUP and MUCP of AUS device in inactivated state were (82.5±30.2) cmH 2O and 51.0(48.0, 77.0) cmH 2O. In the activated state, MUP was (138.9±21.7) cmH 2O and MUCP was 109.0(94.0, 133.0) cmH 2O. Compared with that before operation, the urethral pressure in the inactivated state did not increase significantly (all P > 0.05), while the urethral pressure in the activated state increased significantly (all P < 0.001). The patients were followed-up for 3-33 months. Thirteen patients (86.7%) used the initial installation device, and all of them met the standard of social continence. One patient died of cerebrovascular accident. One patient took out the device due to urethral erosion. The incidence of complications was 26.7% (4/15), including painless hematuria in 2 cases, scrotum and penis infection in 1 case, and urethral erosion in 1 case. The MUP and MUCP of these patients were (100.0 ± 40.7) cmH 2O and (80.8 ± 39.7) cmH 2O respectively. In the intraoperative active state, the MUP was (151.5 ± 15.3) cmH 2O and the MUCP was (123.0 ± 17.2) cmH 2O. The MUP of the other 3 patients in the device activation state was significantly higher than the average value, and all of them were above 150 cm H 2O, except one patient who was infected due to cognitive problems and chronic urinary retention. In 11 patients without complications, the MUP and MUCP were (76.1±24.7) cmH 2O and (55.1±20.0) cmH 2O respectively. In the intraoperative active state, the MUP was (134.4±22.5) cmH 2O and the MUCP was (108.5±29.8) cmH 2O. Conclusions:AUS implantation has a definite curative effect. Poor comprehension, and MUP higher than 150 cmH 2O in the activated state of the device may be risk factors for complications.

2.
Chinese Journal of Urology ; (12): 665-670, 2022.
Article in Chinese | WPRIM | ID: wpr-957452

ABSTRACT

Objective:To explore the efficacy and safety of robot assisted laparoscopic sacrocolpopexy in the treatment of pelvic organ prolapse.Methods:The data of 16 patients who underwent robot assisted laparoscopic sacrocolpopexy in Beijing Hospital from September 2019 to May 2022 were collected. The average age was (73.5±9.3) years, the preoperative course was 4-240 months, the body mass index was (24.2±1.7) kg/m 2, the number of births was (1.7±0.8), and the quantitative index of pelvic organ prolapse (POP-Q) was grade Ⅲ -Ⅳ. The maximum urine flow rate before operation was (9.6±3.4) ml/s, the maximum detrusor pressure during urination was 26 (20, 32) cmH 2O, the first sense urine volume of the bladder was (119.1±39.4) ml, the first sense urine urgency volume of the bladder was (253.6±75.7) ml, the maximum bladder pressure capacity was (406.0±79.8) ml, and the residual urine volume was 10 (10, 28) ml. The preoperative PFDI-20 score was 100 (70, 122) and the PFIQ-7 score was 107 (90, 160). During the robot assisted laparoscopic sacrocolpopexy, the right area of the sacral promontory was exposed, the anterior and posterior walls of the uterus were separated, and the 2 cm small hole was separated from the right broad ligament of the uterus. The mesh was cut into a "Y" shape and passed through the small hole. The anterior and posterior leaves of the Y-shaped mesh were sutured to fix the cervix, and the other end was fixed to the anterior longitudinal ligament of the sacrum. The operation time and intraoperative bleeding were observed. The effect of surgery was evaluated by preoperative and postoperative urodynamic imaging, POP-Q stage, PFDI-20 score and PFIQ -7 score. Results:All the 16 operations were successfully completed. No injury of urethra, bladder, rectum, important blood vessels and nerves occurred during the operation. The average operation time was (255.6±56.0) min, and the average amount of bleeding was (28.8±18.2) ml. There was no inhibitory contraction wave in 7 patients (44%) before operation, suggesting that there was detrusor overactivity. After operation, the detrusor overactivity disappeared or significantly decreased in 7 patients. The postoperative follow-up period was 3-36 months. During the follow-up period, one patient had recurrence, and the rest had no prolapse and urination problems. The POP-Q stage was reduced to grade 0-Ⅰ after the operation. The subjective satisfaction rate of patients was 94%. The PFDI-20 score [13(8, 24)] and PFIQ -7 score [11(6, 15)] after operation were significantly reduced ( P<0.001), the initial urgent volume of bladder (272.5±88.5) ml was significantly increased compared with that before operation ( P=0.038), and the maximum volume of bladder (427.2±79.2) ml was significantly increased compared with that before operation ( P=0.006). Image urodynamics showed that the patient basically recovered the pelvic floor anatomy and achieved functional reduction. Conclusions:Robot assisted laparoscopic sacrocolpopexy has good subjective and objective effects in POP, low recurrence rate and less complications. It needs a larger sample size study for confirming the improvement of bladder function.

3.
Chinese Journal of Geriatrics ; (12): 1407-1411, 2021.
Article in Chinese | WPRIM | ID: wpr-911028

ABSTRACT

Objective:To evaluate the efficacy and safety of robotic arm assisted laparoscopic hysterosacral fixation in patients with pelvic organ prolapse(POP), and its impact on lower urinary tract function.Methods:This study retrospectively analyzed the clinical data of POP patients who had undergone robotic arm assisted laparoscopic hysterosacral fixation at our center from June 2019 to October 2020, and conducted exploratory research.Results:A total of 6 patients were included in the study, with POP quantitative staging above stage Ⅲ.The ages ranged from 70 to 82 years.The number of births each patient had given ranged from 1 to 3, & all were via vaginal deliveries.There were no significant changes in urodynamic parameter scores in any patients before and after surgery, but half of the patients had detrusor overactivity before surgery, which all disappeared after surgery.In addition, synchronous X-ray images showed that the postoperative pelvic organs were closer to the normal anatomical position.At the same time, quantitative staging of POP had achieved clear improvement, and related scale scores also significantly improved.One patient complained of occasional lumbar and back discomfort with postoperative over-stretching during outpatient review, which improved after symptomatic treatment.Conclusions:robotic arm assisted Laparoscopic hysterosacral fixation is satisfactory in efficacy and safety for POP patients, with good postoperative restoration of the uterus to the anatomical position and has insignificant influence on the function of the lower urinary tract.It is worth further assessment for wide application.

4.
Chinese Journal of Geriatrics ; (12): 107-111, 2021.
Article in Chinese | WPRIM | ID: wpr-884851

ABSTRACT

Objective:To investigate the value of serum IL-23 in predicting the progression of prostate cancer at different stages of treatment.Methods:A total of 124 patients with metastatic prostate cancer diagnosed in Beijing Hospital from June 2018 to March 2019 were collected.Patients were TNM-staged according to the Prostate Cancer Guidelines of the European Association of Urology.Serum IL-23 levels were measured in patients with metastatic castration resistance prostate cancer(mCRPC), metastatic castration sensitive prostate cancer(mCSPC)and benign prostatic hyperplasia(BPH), respectively.Patients with mCRPC were subgrouped based on disease stability, and serum IL-23 levels were compared between the subgroups.Serum IL-23 levels in the groups were analyzed and compared with the Gleason score and the prostate-specific antigen(PSA)level.Results:The median value of serum IL-23 in the mCRPC group was 79.73(45.61, 95.63)μg/L, which was higher than that in the BPH group[30.88(15.01, 44.94)μg/L, Z=22.66, P=0.000]and the mCSPC group[46.10(35.27, 80.92)μg/L, Z=11.46, P=0.001]. Serum IL-23 levels were higher in the mCSPC group than in the BPH group( Z=7.17, P=0.007). Analysis for the subgroups showed that the median value of serum IL-23 was 110.25(88.47, 159.09)μg/L in mCRPC patients with unstable disease, which was higher than that in mCRPC patients with stable disease[46.52(44.97, 80.33)μg/L, Z=33.99, P=0.000]. There was no significant difference in serum IL-23 levels between mCRPC patients with stable disease and mCSPC patients[46.10(35.27, 80.92)μg/L]( Z=0.35, P=0.554). Conclusions:Serum IL-23 can be used as a potential biological indicator to predict the therapeutic effect of mCSPC and to predict tumor metastasis.

5.
Chinese Journal of Biotechnology ; (12): 1194-1198, 2008.
Article in Chinese | WPRIM | ID: wpr-275404

ABSTRACT

According to the amino acids sequence of OC-IdeltaD86 gene and Escherichia coli codon usage, we synthesized this gene by overlap extension PCR method with 7 oligonucleotides DNA fragments. The PCR fragment was inserted into pGEM-T-easy vector and the recombined plasmid was named pGEM-T-OC-IdeltaD86. Two oligonucleotides into which the BamH I and Xho I sites were introduced were designed and synthesized based on pGEM-T-OC-IdeltaD86 and pet21b, and the PCR fragment into which the BamH I and Xho I sites were introduced was obtained. After digesting it with BamH I and Xho I, OC-IdeltaD86 gene was cloned into the corresponding sites of pet21b and obtained prokaryotic expression vector pet21b-OC-IdeltaD86. OC-IdeltaD86 gene was expressed in E. coli (BL21(DE3)plysS) after IPTG(Isopropyl beta-D-1-thiogalactopyranoside) inducement for 5 hours. The fusion protein of OC-IdeltaD86:6His gene accounted for 11.4% of total protein and 16.4% of soluble protein, which had been successfully purified by Ni-NTA and concentrated by PEG20000. This protein can effectively inhibit papain activity in vitro and may be used in anti-nematode research in vivo.


Subject(s)
Cloning, Molecular , Cystatins , Genetics , Cysteine Endopeptidases , Metabolism , Cysteine Proteinase Inhibitors , Genetics , Escherichia coli , Genetics , Metabolism , Genes, Plant , Genetics , Mutation , Oligonucleotides , Genetics , Oryza , Genetics , Papain , Prokaryotic Cells , Metabolism , Recombinant Fusion Proteins , Genetics , Metabolism
SELECTION OF CITATIONS
SEARCH DETAIL